House · aparthotel · commercial · industrial

Installation, piping and commissioning of building engineering equipment

We install equipment from any manufacturer — from a multi-split in an apartment to a chiller with fan coils in a hotel. Not just “hang it and plug it in”: correct piping and connection, hydraulics, wiring, controls and commissioning, so the equipment runs to its rated specs and lasts its full service life.

WhatsApp
Installed boiler room equipment: water heater, boiler, piping and connections
Indicative price from 250 GEL Split system installation up to 12 000 BTU. 6–10 kW heat pump with piping and start-up — from 3 500 GEL
  • 12equipment types
  • from 250 GELsplit system installation
  • 5 yearsinstallation warranty

Equipment we install

EquipmentWhere it is usedWhat we do
Heat pump air-to-water, 6–30 kWhouses, aparthotels — heating, cooling, hot waterbase/bracket, hydro module, buffer tank, water heater, piping, 1-phase/3-phase wiring, setup
Multi-split, 2–5 unitsapartments, small houseslines in wall chases, drainage, brackets, evacuation, start-up
VRF / VRV, 8–100 kWaparthotels, offices, villasline design, refnets, mains, nitrogen brazing, 40 bar pressure test, addressing, controllers
Chiller + fan coilshotels, shopping centres, production sitesbase, hydraulics, pump group, fan coils, piping, controls
Supply-and-exhaust air handling unit with heat recoveryapartments, houses, cafés, officessuspension, ductwork, grilles, air heater, CO₂-based controls
Air heater water/electricsupply air, warehouses, workshopspiping with a control unit, frost protection
Boilers gas, electric, solid-fuel, cascadeseverywhere — see boiler roomsinstallation, flue, piping, handover to the gas utility
Water treatment and purificationhouses on a well, hotels, caféswater analysis, filters, softener, iron removal, UV, reverse osmosis
Booster pump stationupper floors, houses, hotelspump, pressure tank, pressure switch/VFD, bypass, piping
Fire and security panelscommercial, hotels — see low-voltage systemsinstallation, loops, detectors, programming

Why installation matters more than the brand

A $8 000 heat pump with a wrongly sized buffer tank will short-cycle and wear out in three years. A VRF system with lines brazed without nitrogen will lose its compressor within two seasons. A split with a drain line without a trap will smell of sewage. We install to the manufacturer's instructions and engineering practice — and give a 5-year warranty on our work, which only makes sense when the installation is done right.

Brands we work with: Daikin, Mitsubishi Electric, Panasonic, Gree, Midea, LG, Haier (climate); Panasonic Aquarea, Daikin Altherma, Vaillant aroTHERM, Gree Versati (heat pumps); Systemair, Salda, Blauberg, Vents (ventilation); Grundfos, Wilo, DAB (pumps); Aquaphor, BWT, Ecosoft (water). Most often we install Midea, Gree and Daikin.

Scope of work

What installation includes — by equipment type

Heat pump

Base or brackets with anti-vibration mounts, condensate drain (heated in winter), hydro module, 100–300 L buffer tank, hot water cylinder, pump groups, three-phase supply if needed, heating curve setup, handover.

VRF and multi-split

Line design with length and height-difference calculations, copper to standard, refnets, brazing under nitrogen, pressure testing, deep vacuum, additional charge by line length, condensate pumps, addressing, controllers, central control.

Chiller and fan coils

Base, vibration isolation, hydraulics with or without glycol, pump group, tanks, filters, fan coils with control valve sets, drainage, controls, balancing.

Ventilation units

Suspension on vibration isolators, insulated ductwork, silencers, dampers, grilles and diffusers, air heater with piping set, control panel, commissioning by airflow.

Water treatment and pump stations

Water analysis, selection of treatment stages, vessels, piping with bypasses, regeneration drain, pump with variable frequency drive, pressure tank, dry-run protection, pressure setup.

Fire and security panels

Panel installation, loops, detectors, sounders, zone programming, testing, connection to monitoring. More in low-voltage systems.

Prices

Equipment installation prices

Labour only, excluding equipment, unless stated otherwise. We supply equipment at dealer prices or install yours.

Work / itemUnitPrice, GEL
Split system 7–12 / 18–24 kBTU, standard installation, up to 3 m of linepc250 / 300
Air conditioner line beyond 3 m (concealed, in a wall chase)lin. m50–60
Multi-split: indoor unit / outdoor unit up to 60 kg / over 60 kgpc150 / 300 / 400
VRF: indoor unit with connection and drainageunitfrom 500
VRF: outdoor unit, mains, refnets, nitrogen, vacuumper kWon request
Heat pump 6–10 kW: installation, piping, start-upkitfrom 3 500
Heat pump 12–16 kW with buffer tank and water heaterkitfrom 6 000
Chiller 30–100 kW with fan coilspropertyper design
AHU with heat recovery 300–600 m³/h: installation, ductwork up to 20 m, controlskitfrom 3 500
Air heater with control unitpcon request
Booster pump station with pressure tankkitfrom 1 500
Home water treatment: sediment filter + softener + UVkitfrom 1 500
Reverse osmosis, under-sink / commercialpc150 / on request
Commissioning of equipment installed by othersvisitfrom 1 000

For aparthotels and properties with 10+ indoor units — project pricing with a volume discount. Air conditioner cleaning — from 150 GEL.

Need an exact estimate?

Send us a floor plan or photos of the property — we will calculate quantities and send a cost estimate with materials within 24 hours.

How the work goes

How installation works

  1. 01Sizing check

    We check whether the chosen equipment suits the property's capacity needs, hydraulics and electrical supply. We often save the client money before the purchase.

  2. 02Diagram and estimate

    Piping/line diagram, bill of materials, labour price. For VRF and heat pumps — a design.

  3. 03Preparation

    Embedded parts, lines, cables, bases — at the rough-in stage or in a finished space with minimal disruption.

  4. 04Installation and piping

    To the manufacturer's instructions: tightening torques, vacuum, nitrogen, slopes, vibration isolation.

  5. 05Commissioning

    Start-up, parameter setup, measurements (pressure, temperatures, flow rates, currents), start-up report, user briefing.

Choosing

Heat pump, VRF or multi-split — what suits your property

Apartment 50–120 m² — a multi-split with 2–4 indoor units for cooling and shoulder-season heating; main heating from a gas boiler. No gas — an air-to-air heat pump (the same splits in heating mode) or a 6–8 kW air-to-water unit with underfloor heating.

House 150–300 m² — a 10–16 kW air-to-water heat pump for underfloor heating, a hot water cylinder and passive cooling in summer; plus 2–3 splits in the bedrooms. With gas available — the heat pump as the main source and the boiler for peaks: in Batumi a heat pump with a COP of 3.5–4 is cheaper than gas for most of the winter under the tiered tariff up to 300 kWh.

Aparthotel, office 300–2 000 m² — VRF: one outdoor unit for 10–60 indoor units, individual control in every room, per-room metering, compact lines. Ventilation — AHUs with heat recovery for corridors and common areas.

Hotel, shopping centre, production site from 2 000 m² — a chiller with fan coils and central air handling units: cheaper per kW at high capacities, easier to maintain, one chiller instead of a dozen outdoor units.

Supply example: a multi-split with 4 indoor units (2 × 9 000, 1 × 12 000 and 1 × 18 000 BTU) and a 42 000 BTU outdoor unit — equipment from the manufacturer 12 450 GEL.

FAQ

FAQ — Equipment installation and piping

Will you install equipment I bought myself?

Yes. Send us the model before you buy — we will check sizing and compatibility with your property; if it is already bought, we will inspect and install it. We give a 5-year warranty on our work; the manufacturer's warranty applies under the manufacturer's terms.

Does a heat pump work in Batumi in winter?

Yes. At −5…+10 °C modern inverter heat pumps hold a COP of 3–4, meaning 3–4 kW of heat for every 1 kW of electricity. Winters in Adjara are mild — almost ideal conditions. In the mountains (below −10 °C) we plan a backup heat source.

How much does maintenance cost?

Split system cleaning — from 150 GEL, heat pump or VRF servicing — from 300 GEL, AHU filter replacement — from 300 GEL.

Do I need permission for outdoor units on the facade?

In most residential complexes — approval from the management company (location, bracket, drainage). In Batumi's historic centre facades are protected — we hide units in the courtyard or in screened enclosures. We will advise on site.

What about well water — rust, odour?

We do a water analysis and select treatment stages based on it: iron removal, softening, carbon, UV. We do not sell filters without an analysis — that would be money thrown away.

Water pressure on the upper floors is weak — can you help?

Yes: a booster pump station with a pressure tank and VFD, piped with a bypass. For an apartment — a compact pump with a flow switch; for a house or hotel — a twin-pump station with redundancy.

Need an estimate for your property?

Describe the job — we will work out the scope and propose a solution within 24 hours.

+995 593 153 647